Murray / Crouse Hinds have made breaker panels for many years however their MP main line series panels made in 80s and 90s have a serious design problem with 150 amp and 200 amp Main breakers burning up or not turning back on after being turned off after being on for a long time
The problem starts when the main breaker which is stabbed on instead of bolted on to the panels buss bar becomes loose after heavy amperage draw thru it
As you can see in the above picture the stab blades on the breaker are all burned up.
This leads to arcing and smoking and buzzing noises and eventually breaker failure and out go the lights .
Normally the damage is too bad to save panel as buss bar is also damaged and requires total replacement which runs into the thousands
If you have one of these panels have an electrician who has a thermal camera check to make sure your main breaker is not failing
Luckily Murray has come out with a new line of panels which now have bolt on mains and this problem is eliminated