Sunday, July 28, 2013

WI-EX Cell Phone Booster and Luxul Networking equiptment brings High Tech to the New Life Church

One of my new customers who I meet thru a Electrical Contractor  The Electric Company introduced me to  the New Life Church in Saxonburg Butler County Pa. has finally been able to save enough funds to build a  new church after meeting at a school for many years . But with all new buildings there are challenges especially since technology and building codes  is constantly changing the church wanted to take advantage of the new technology but try and stay in budget but also allow for continued growth as buildings are added  .



With this in mind I installed an integrated Honeywell System which consisted of a Honeywell Vista 250FBP panel  combo Fire and burglar alarm panel  which is Total Connect 2  services  activated which also provides the Vista Key Access system and  a Silent Knight Voice Evacuation panel with 6 zones  with a big facility being able to give clear voice commands is essential . I also installed an Avaya IP  5 Office  Phone system which can be upgraded to full IP service which is fully expandable .




But I also added some new technology to make  life easier in the church while they had a simple Belkin router set up to get them thru they needed professional networking gear thats where after doing research and working with many manufacturers I settled on Luxul  for router switches and access points high end self configuring components made it a breeze for half what you pay for Cisco and it blows Cisco out of the water




Luxul Router and 2 24 port gigaswitch

WiFi Access Point
But then with all this neat stuff we had a problem no cell service inside the building because of its all metal outer shell walls thats where Wi-Ex  products come into play I used a High end unit YX745 only available to professional installers which brings the outside cell signal into the building by means of a outside mounted antenna and inside mounted amplifier and antenna and it works great





inside amplifier and distribution antenna

outside PCS and GPRS antenna
 looking for solutions check out these company's and there great products

Monday, July 22, 2013

Why Spiral staircases in Fire Houses Another Horse Poop Myth Busted

There is a factoid article running around on the internet that Spiral staircases where put in Fire houses to keep the horse from trying to go up  stair cases   and eat the fireman's food when they smelled it.
a Total and complete myth  but it makes for a good story .

The Myth is total horse manure


The Truth is Spiral Staircases where put in to allow  for more floor space  in the house  since equipment was getting bigger  and needed more floor  space and besides horses where kept in locked stalls in the house  not loose walking around which most fire houses when built in late 1800's where utilizing horses  already to pull units around like hand pumps , hose carts and ladder units  not just steamers, Horses could get units there faster . Horses also will not go up steps voluntarily let alone go up several flights  you must force them to  as a rider or be pulling them on a leader they do not like steps for that matter many horses do not like walking over storm sewer lids either on the street. Horses are also not carnivorous therefore they have no desire for human food  . I have helped my sister in law with her horses for many years now . Other than a horse getting nosy as to what your doing they  are strong independent animals ,who keep to them selves  for the most part. Once again a good story  going around on internet like using egg whites  to treat burns both story's  and no truth to them check the facts out for your self do not believe what you read on line from one source and then buy it hook line and sinker.


Saturday, July 20, 2013

Who is the JACK ASS at Boy Scouts who thought up no Obese scouts at the National Jamboree ? I think I know why and talk about discrimination.

Yes it is all over fox news 7-15-13 about obese scouts will not be allowed to participate at this years national jamboree. I am totally and completely appalled , disgusted and ashamed to point I am ready to turn back in my Eagle Scout Award  because this is so wrong.





So tell me again how this is not discrimination because this also means Handicapped Scouts will not be allowed also since it is such a physically demanding jamboree.

Did any of these uncaring fools AT SCOUT COUNCIL  hear of the American with Disabilities acts.

Young boys come in all sizes all colors all religions etc. etc. This means you all work together and you do not discriminate. Do they realize the head trip and psychological damage they are doing to young men who want to do right . Some kids will never be thin no matter how hard they try do to certain medical conditions  what the hell are they thinking to loose weight requires more than ok stop shoving food in your mouth.

I hope the parents of these obese and handicapped scouts sue the living shit out of the  boy scouts as well as the justice dept.  for violating civil rights  .

Yes I know all about how scouts discriminate because as a  scout I had asthma , dyslexia and knee problems and I would have hoped it all went away by now but obviously it never did .

When they where selecting a scout to go to the North Pole they said my health issues would interfere.

How the camp leader got mad I wore long pants to protect my legs during day from injury after surgery on my knee that spring  when on camp staff instead of shorts like everyone else as I did not fit in and look the same  TOO FUCKING BAD  I have a right to protect my legs and OSHA  requires it. If your think BSA is exempt from OSHA rules thats what you think.   Plus  I got the job done plus more than most scouts did keeping Semiconon and other camps running .I got my eagle scout despite my disability's. Scouting is not about all being the same its about being a good and proper citizen  and you can do it if your black , white gay straight fat or crippled .

In the Silver Tip District we had a scout leader in a Wheel Chair and we saw that he got to as many events as possible and young scouts took turns pushing him around and taking care of him. He even went in march of dimes walk a thons with us and scout council members resented it as no other district did it.

Same thing with  in Fire Service heard it from the assholes at Penn Hills Station 224#  why is Nick a member when he can not go in and fight fires and can not complete some of the drills . No I could not but I could drive and pump the truck and handle all the outside work while those who could do the inside work did there job instead of being stuck having to run the truck on calls when your short handed.


You know what all these  ignorant ass holes who think I should not have worked with them because of all my health issues  I got news for you at 54  a Stage IV Colon cancer Survivor I  am still  working part time  in the new and old construction field wear a White Hard Hat, Safety Glasses and Steel Toes There are no shorts on construction sites except on really hot days depending on the job you do.
 Yes thats right I work on construction sites right next to a master electrician who is 75 years old on a job where we have to work and pull wires in place 45 foot in the air  from a shaky  scissor  lift platform  working around live 480 volts of AC Power  one mistake could be our last and I see plenty of young athletic men come on job and are afraid to go up and work that high  they will not even get on the platform or come near the live wiring .
Why do we do it ?  Because our skill sets are very valuable and all ages  all abilities we all work together on the job site to get it done  .Yes us older guys have to take more breaks then the young workers but in the end we get it done , something scouting and fire service  has never obviously ever learned the value of the person vs how the person looks or acts. Now that I am in a senior tradesman position I pass my knowledge down to the younger generation of workers and make sure they do there work safely and come home each night to there family's like the old guys who guided me.  We do not care what you look like we do not care if your a felon we do not care if your gay or straight  black white or pink  or purple  we care about one thing get the job done for the customer on time and on budget when possible and go home safe and in one piece. We even have women working right besides us and some times bossing crews all we care about is getting it done, and working together to get it done we keep our personnel issues at home and know each others capabilities and get it done working together.There is nothing like at the end of the day looking at that building you helped build  and then being able to tell your grandchildren about it.

Thats the way this jamboree should be run and those able scouts should be working to make sure the handicapped and obese scouts are able to due there best as well encouraging and  working right beside them instead of excluding them in these physical tasks They should be learning together and working together to make it a better world so everyone gets along.
 BUT THE REAL REASON BEHIND IT !
But I think  I know the real reason behind this its a way to back stab the GLBT Groups yes think about it  The perception  that most  young gay boys are fat . Yes I said it thats what the straight community thinks what better way to keep gay scouts out than by banning the obese when so many gay boys are perceived to be obese. I may be totally wrong but where there is smoke there is sometimes and this is despicable if this is what they thought up  .
  

Yes once again the Boy Scouts of America is proving everyday why it should no longer be in business when it pulls a stunt like this and you can believe me when I tell you if I ever had a son he would not have been a scout.I would not allow him to go thru what I did because of my disabilities.

For more thoughts and experience from my scouting days check out my lone eagle scout blog







Wednesday, July 17, 2013

Blown in Foam Insulation - Should we be derating electrical wires running in it?

You see it in almost every new home and in some Commercial construction  a new style of blown in foam insulation  which totally seals off air leaks in homes and is an excellent energy saver. The problem thou is there is now no air movement around the romex wiring in homes walls which I worry could eventually result in fires when wiring overheats .





We saw a rash of these problems in the 1970's during the Carter Administrations  Energy Crisis when many home owners with homes which had no insulation got cellulose insulation blown into there homes walls and the result the Knob and Tube wiring which is designed to have air flow around it so a 14# gauge wire can be fused at 25 amps unlike Romex type wires which would have to be protected at 15 amps.


Overheated and caught homes on fire. So it finally became practice to d-rate wiring in these old homes and lower the fuse to 15 or 20 amps to prevent problems and add circuits and upgrade the services.

All electrical equipment is designed to have some air movement around it same way when we put wiring in pipe we must allow an airspace  as well to allow wires to expand  and this is what I worry about as you can see in the picture the entire electrical equipment is saturated with the foam theirs no expansion and no air flow.

I am not the only one worried I have talked with numerous fire officials , electricians and engineers etc. and all have concerns yet I have seen no action by any group or organization to look into this possibility. Guess where going to have to find out the hard way like we did with aluminum wire and plastic water pipes and flexible gas pipes   and then what about the hundreds of thousands of homes which already have this foam in place? Yes once again no one wants to look at this discuss or examine it till its too late what a dam shame there should have been plenty of research done on this before it was ever used. When I have concerns like this it usually proves true and as usual  I will be there saying I told you so.

Sunday, July 14, 2013

If you own a Business you need Flood Insurance even if you think you do not

I found out in 2004 even living 1200 foot above sea level you can have flooding in your basement .
After Hurricane Ivan left 3 inches in my basement luckily nothing valuable got damaged  and it took a while to clean up but I learned my lesson  when drains could not handle the water and now store everything up from the floor.
How ever one of my customers a High End Furniture Store was not so lucky and had a Million dollar inventory of exclusive furniture brands either destroyed or water damaged when severe storms hit the south hills of Pittsburgh This week.. They where able to save some things to resell at a loss but the big problem now is with there insurance company who does not want to cover anything saying even thou floor drains backed up it was an act of god because it happened during a horrific storm so its flooding because the underground creek tunnel near there store would not allow the storm waters to go down because it was full.  Sorry thats not the way there policy reads so they are going to have to sue them like they did last to get to get coverage. In mean time they are left with cleaning up a soggy mess and covering all costs till they prevail. there insurer is even fighting them on the business interruption insurance they had as well .  Having to deal with the total scum so called Restoration contractors who prey on flood victims is another problem as well while trying to clean up there just as bad if not worse than dealing with insurance company some do there job right most just rip you off just adding to the misery. For the most part in my opinion insurance company are the scum of the earth except for a couple of stand outs who take care of there policy holders. Then again there smaller company's who do not spend millions on advertising.
This is why it is imperative you purchase flood insurance if you are any where near a water source that can flood into your business or home for that matter  because otherwise your insurance carrier is going to try and wiggle its way out of covering you claiming act of god or its flooding not backed up sewage etc.
Even for business the insurance is affordable but there are some areas who can not get it . even if they do want it and have the choice always live with chance of flooding and deal with it or move.


Below are general pictures of flooding  that happened on 7.10.2013 in bridgeville are along Chartiers Creek  and Mayview & Boyce Roads I passed  while traveling to assist my customer.


a normal babbling creek now a raging torrent still 2 days after storms

wood and debris brought down when creek flooded road


Yes thats an actual gazebo which flowed down the creek




Dangerous Electric Range Wiring leads up to to Buyer Be Aware on pricing at Lowes Home Improvement Store

A good friend and long time customer Jim called me Friday and asked if I could come over and fix his electric range wiring  as it was direct wired instead of with a plug and cord he found this out in preparation for new range being delivered on Monday morning from Lowes . Sure no problem I told him some one being cheap doing it that way I would be over Saturday .So I picked up a 50 amp range plug and cord set and get there in the after noon what should have been a 20 minute job ended up a nightmare . Ends up not only had they wired the range with out a proper plug and cord the wiring was undersized. it was 10/3 good for 30 amps  and wired improperly with ground and neutral wire together there was no connector allowing wire to rub and get abraded  and it had been spliced under the floor some where. It appears this was the 30 amp electric dryer line the kitchen SLOB contractor  reused instead of putting in proper wire .Thank God he is dead and not causing more dangerous situations .
 This range should have had a minimum of a 8/3 wire for 40 amps and with the new range being even bigger it was imperative the wiring be changed. Well its Saturday all the supply houses are closed we go to Lowes knowing we would pay a little more for the wire  but he needed it done. We go back the electrical aisle and see the big sign above the rotating  rack with wire samples  and locate 8/3 romex with little yellow tag next to it marked $1.18 per ft. OK about 50 cents higher than I pay a foot at supply house cut by foot so he buys 100ft of cable since I had to make a circuitous route around the solid tiled ceiling to get to range .
But when we get to the check out its $2.39 per ft. What the Fuck. I go back and with store clerk here on the actual rack where wire was stored there is a separate sticker of  $2.39 you only get the $1.18 price when you buy the 500 ft roll.
needless to say because they did not clearly have this displayed and clerk who pulled wire for us did not advise us this big discrepancy it is clearly a violation of fair trade practices of Pa. consumer protection laws prices have to be clearly posted. I have contacted them and plan to follow thru what ever is needed to see this practice stops and wire is clearly marked. My customer agreed to buy the wire  despite getting screwed on the price I told him to wait till Monday morning and I would do it  but he needed the wiring ready for new range Monday because he was not going to be there just his wife and was worried they would not wait for me to Finnish it up  so they could hook it up on Monday. Some supply house charge a cut fee for loose wire but known of them charges double per foot of wire to cut it this is a clear rip off . Needless to say Lowes will never again see a penny from me in sales. and I am no fan of home depot either having been ripped off several times by them but they did make it right.

When dealing with Obsolete Electrical Gear its wise to use a Chicken Switch

all thats left of insulators on single phase transformer
Recently at one of my  Industrial customers who recycle oil they suffered a lightning strike which damaged  some of the electrical gear . At the front of the building a lightning strike took out and destroyed a pole mounted Transformer killing the 230/120 volt lighting circuit to the plant. Luckily a generator kept things working and there was little damage because I had installed whole panel surge protectors on most of the panels the one I had not gotten to in the lunch room they lost a microwave oven and the old fuse panel was damaged. It will soon be replaced with a breaker panel insert and surge protector put into it .
e
Damaged lunch room fuse panel
After the power company came and restored power at 9:30 Pm  I walked thru plant checking everything and other than tripped surge protectors  everything was working  I reset the surge protectors and thats when I noticed the Three Phase 480 volt Delta system was not restored at that late hour I was not going to call Duquesne Light  Power Company workers   back in plant and manager said he would call them back in morning out of safety concerns.
Morning came and I meet up with Duquesne Light Workers at back of the plant they had tested the 5000 KVA  32,000 to 480 Delta to delta Transformer which provides 1200 amps of 480 3 phase power to the plant  and all 3 fuses where out . They replaced the fuses in this very old transformer from when this plant originally made Steel drums and barrels   and where worried about turning it back on the switch to control it was located with in the sheet metal enclosure they asked for a hole saw so they could cut a hole and run a rope to outside so they could pull the switch from a safe distance away . What they made is whats commonly known as a chicken switch it allows potentially dangerous items to be turned on from a safe distance. If you watch the TV program " Sons of Guns " on the Discovery Channel  when they test big guns and cannons first time its the same ideal.
Well they setup the rope worried over how old this transformer was possibly bad since all 3 fuses blew and good thing they did after pulling the rope there was a tremendous loud explosion and big blue flash and smoke  followed by a second one 20 seconds later. 40 foot away I was nearly knocked off my feet . The blast was so strong it damaged nearby freon lines for an HVAC unit even if the utility workers had on a blast suit made for working around high voltage they would have been seriously injured had they stayed with in the enclosure surprisingly the heavy steel casing of the transformer did not blow apart but  the rear 480 volt secondary insulators on back where blown apart.
In this case it was absolutely the right call to use a chicken switch or some one could have died very easily. After the blast the power company workers went to work quickly to replace the transformer but did not have an immediate back up replacement so they brought in a back up replacement trailer which serves as a temporary transformer
Portable Transformer
and with in 12 hours power was restored . During turning the 3 phase back on and inspecting things I found a 200 amp distribution switch off the buss severally damaged I was temporarily able to get it working again and will be replacing it shortly when a new unit is located and a compressor was damaged. needless to say seeing how el the surge protectors worked in the rest of the plant they  want me to install surge suppression all over the 480- 3 phase system to protect it from future issues.

Damaged compressor control