Friday, July 9, 2021

Do you have a Hik Vision or Dahua or one of their many 3rd party relabled Survielance camer system. Do You know its been banned by FCC and other federal agency do to Chinese having a secret back door and do you know the dangers this means to your business.

 So Big bad US Government has banned Hik Vision  and Dauhau Surveillance Camera  Products 

if a Camera Product is not NDAA compliant it can not be used by a government entity.

This is because of a known issue with a back door in the systems which allow Chinese access to your computer Network for spying or causing damage like ransomware.  

https://ipvm.com/reports/ndaa-guide

https://ipvm.com/reports/ban-law

 

While some security dealers scoff at it and say its propaganda and nothing to worry about

They are sadly misinformed into danger these units pose . Yes even the corner Pizza shop is vulnerable  

 which is one of their arguments

I recently had to tell the President of a large telephone / cable company in W. Pa  who trusted his security company to do him right he had been screwed as they installed Hik vision cameras in his brand new headquarters and he blew his stack because he has been going thru and making sure he had no banned Hewaii  switching system equiptment in his operatoions and his security supplier goes and screws him.

Well after doinOf course our own uncaring Allegheny County District Attorney when made aware his office was using Hik vision products and he said he was not concerned.

If he would bother to do some simple research he should be,so let me tell you what the dangers are.

and how he has screwed the citizens of Allegheny county. 


1st off  if your that little Pizza shop Owner  and you think your not being spied on by Chinese Think again 

They are watching all kind of business to look for vulnerabilities  like when you make your cash drops 

they know when you open when you close they know where your safe is  watching your cameras info that could be passed on to a criminal organization

 2nd off they know who you buy from  and if your a franchised pizza shop all the better because these hik vision  units could allow a tailgating or piggyback attack  of your franchises network.

. This is exactly how Target Retail stores where attacked one of their vendors a Mechanical contractor in Pittsburgh who got work orders and submitted bills etc thru Targets network  was hacked then this opened the door to the target network.

https://krebsonsecurity.com/2014/02/target-hackers-broke-in-via-hvac-company/

 3rd My camera vendor said he isolated and blocked the Chinese from being in my network

Think again do you use a phone app like Hik Connect guess what all the isolation you are doing is worthless they have everything they know from the phone App


4th Hik and Dauhau has been called out by  US state Dept. for using Slave labor to build their products thats why they are cheaper than everyone else  as well as allowing china to spy on its own citizens activitys

https://news.trust.org/item/20210709012916-ql13s

 

5th Hik and dauhau have been delististed by Onvif the agency which sets standards for IP based Camera Systems 

The big Problem also is Hik provides components to many manufactuers  so your cameras may not say Hik or dauhau but they can still be on list and disreputable dealers are taking full advantage of using 3rd party labels.  

https://ipvm.com/reports/dahua-oem

https://ipvm.com/reports/hik-oems-dir

 

The list is extensive and many popular manufactuers in above links if you are using them you are at risk.

It looks like Hik and dauhau are shutting down operations in US  and thats a good thing but all that legacy product out there is going to cause problems for years to come.

 

 

 

Nice idea take an old refrigerator turn it into a food pantry box. Bad idea your potentially violating state law and putting young lives at danger.

 The North Braddock Community came up with this really nice idea take an old Refrigerator and turn it into a community Food Pantry and the kids did a great job on it.

Which will be located on 6th ave. according to Face book Post

Only there is a  Problem


 

Being left outside and unsupervised a young child could become trapped in it if playing with friends and things get out of hand . and it potentially violates state laws regarding unused and abandoned refrigerators . Which was put in place after children lost their lives playing around and unintentionally or intentionally being trapped in an old refrigerator that was left out on a porch etc. 

§ 6502.  Refrigerators and iceboxes.

(a)  Offense defined.--A person is guilty of a summary offense if he discards or abandons in any place accessible to children any refrigerator or icebox having a capacity of 1.5 cubic feet or more with an attached lid or door, or being the owner, lessee or manager of any place accessible to children knowingly permits an abandoned or discarded refrigerator, icebox or chest to remain there with an attached lid or door.

(b)  Effect of violation.--A violation of this section shall not in itself render a person guilty of manslaughter, assault or other crime against a person who may suffer death or injury from entrapment in an icebox or refrigerator.

Now if they stripped it all out and put a couple holes to insure if a child gets trapped  they wont suffocate that may fly but I still would not put anything out a child could get trapped in. That's why most outside pantry's are smaller and up on poles or posts. 

Myself and others expressed our concerns on Facebook and i saw it outside on porch of the Braddocks Battle field museum today. Hopefully they will rethink this and se if it can be put inside museum where it can be supervised.  

In mean time great job those who painted it.


Monday, June 7, 2021

Low Voltage explosion Proof wiring Installation which is total disaster waiting t happen. No wonder so many problems at plants with explosive products.

 I often work in plants that have explosive  and dangerous atmospheres where specialized explosion proof wiring is required.

All too often these installs are totally wrong and will not prevent an explosion and can actually cause them.

Take this latest facility I was working in an old pain manufacturing plant on Neville Island .

A well known national alarm company with 3 initials  failed when it came to installing the fire alarm system in a 

Class 1 Division 1  area of the plant.

First off although they use the correct explosion proof Tamper Switch on the valve the Sprinkler System the flexible plastic is incorrect it has to be metal seal-tight that is gas impermeable .

https://www.larsonelectronics.com/blog/2018/11/13/explosion-proof/when-to-use-seal-offs-and-barriers-for-explosion-proof-equipment/


Second the seal off as seen below which prevent explosive gasses from back flowing thru the rigid steel pipe is not filled with the cement type  compound  all around wires that seals off the pipe .

This company had no business installing in a hazardous atmosphere unless they know what they are doing and its very clear they do not .

I see ppeople posting all the time in alarm groups on social media asking about hazardous and explosive 

setups and when i tell them to employee an electrician who is trained and knows how to do this work they get offended.

You have no business install in these atmospheres unless you fully understand the NEC Codes .

and I just don't see this with low voltage I see it all the time with higher voltages which is really scary.



Monday, May 31, 2021

Another Slob HVAC contractor install this time at a Basketball Training Facilty.

 My customer has had a bad run of luck with contractors with his new basketball training facilty .

This time its the way the HVAC system was installed

First off they used the wrong wire type since everything is pen and exposed in this facility it has to be physically protected . so NMC- Romex is not permitted 

So that's first error they made. 2nd they never installed an outside disconnect on condenser unit so it can be safely serviced.

Plus to make it more dangerous they brought the plastic jacketed romex out to condenser thru the metal building with no sleeve to protect it and the wire is not rated for outside use.


Then although your allowed to use PVC to vent the high efficiency furnace. Your not allowed in this facility it has to be metal  exhaust pipe and metal  drains . due to fire spread from PVC  as its a high occupancy place.

The contractor is a total slob residential guy obviously never did commercial work because he would know better .

Needless to say the owner is very upset and contacted the company to get it corrected.

If not next call will be building inspector.




Step Ladder sold by Home Depot with neat feature is also very Dangerous to users of the ladder un aware it is not properly secured.

 I was working at a customers oil distribution facility  recently and needed a short step ladder to install an WiFi Access point when customer said go ahead and use one in warehouse .

Walked out into warehouse and there sat an impressive well built aluminum  step ladder approx 4 ft tall just perfect for what I needed .

Customer said he bought it from Home Depot   and made by the people who make the Gorrilla Ladders


It even had this neat Flip Tray feature which was great so I could put my self drill screws in tray  


So I put my screw in tray get up on ladder and that's when I realize the Flip Tray is not locked in place as I bump against it and the tray opens and screws go everywhere and I loose my balance. 

Luckily I was not hurt but I could have easily been so.


This feature although handy needs to be latched down so  it can not be accidentally opened and products in tray thrown all over the place.

The intent was correct but not the design.

I will be notifying CPSC and home Depot  about this design flaw so ladders can be recalled and corrected a feature like this needs a latch .